Remember these 10 moves! Whether you are an electrical diagram or a wiring diagram, everything is wrong - 3

  • 27 March 2020

These are all the knowledge that SUPERNOVA has accumulated only after 20 years of focusing on a career. I think you've read the article "drowning 3000, how many ladles can you take to drink" a few days ago. How many skills can you master? No matter how many interests you can choose, no matter how many ideals you can't achieve, no matter how many careers you can choose, only those that are suitable for your own development, and no matter how many successful paths you can choose, it's estimated that you can only choose one of them. In this life where flowers are becoming more and more attractive, there are tens of millions of paths. How many can you walk? Don't talk much, let's start!

5. A kind of The main circuit wires and power lines shall be marked in yellow, green and red, and the power lines with working voltage of AC380V and above shall be connected with black wires; the power lines with working voltage of AC220V shall be connected with red wires, and the 0V common terminal wires shall be connected with white wires; the power lines with working voltage of DC24V and below shall be connected with blue wires, and the current transformer wires shall be connected with Color line.

⒍ the grounding conductor of the components in the electrical cabinet shall be grounded independently, and parallel connection is not allowed. For the electrical cabinet with frequency converter, the grounding of frequency converter shall be separately grounded with PLC control circuit. In case of no guarantee of independent grounding, in order to reduce the interference of frequency converter to controller, the control circuit grounding can float, but the frequency converter must be reliably grounded. In addition, the shield wire in the control system also needs to be grounded.

Welcome your consult to know more:

Kevin

info@jntime.com

Tel/Whatsapp: +86 13606411517